Product safety reportOPSS
CCM Premier 92 HPM Premier 92 M10 Paper Guillotine safety warning over an injury risk
Product Safety Report for CCM Premier 92 HPM Premier 92 M10 Paper Guillotine presenting a serious risk of injuries.
Check your product
Only products that match these details are covered. Have your pack in front of you.
CCM Premier 92 HPM Premier 92 M10 Paper Guillotine
- Sold betweenCompare with your receipt or order date.
- CCM Premier 92 sold between 2020 - 2021, HPM Premier 92 M10 sold between 2020 - 2021
What to do now
CCM Premier 92 HPM Premier 92 M10 Paper Guillotine has been reported because it could hurt the person using it.
- Stop using it.
- Read the corrective action below: some notices offer a fix rather than a return.
- The marketplace has removed the listing. Contact the seller through your order history to ask for a refund.
- If you cannot reach the seller, Trading Standards can be told through Citizens Advice.
Why it matters. Products that break, pinch, cut or fail suddenly can cause injuries ranging from cuts to fractures.
Getting your money back
Sellers on online marketplaces do not always run recalls themselves, so you may need to ask for your money back. The platform’s help pages explain its buyer protection scheme.
Citizens Advice (0808 223 1133), Advice Direct Scotland (0808 164 6000) and Consumerline (0300 123 6262) give free advice if you get stuck.
From the official notice
Published by the Office for Product Safety and Standards (2608-0035). Quoted as issued.
Summary
Product Safety Report for CCM Premier 92 HPM Premier 92 M10 Paper Guillotine presenting a serious risk of injuries.
The risk
The product presents a serious risk of shearing injury to the upper limbs because the required safety distance between the guillotine blade and the left-hand light curtain (Electrosensitive Protective Device) is not met.
The machine is also inadequately guarded at the rear. It does not effectively prevent access to the knife and back gauge during operation because it has a removable guard not requiring tools to open it and its single sensor interlock did not meet the dual channel sensor requirement and safety performance level in BS EN 1010-3:2002+A1:2009, now replaced by BS EN ISO 1264-3:2023. Side access to the back gauge drive spindle is also possible. The two-hand control with a single contact per switch connected to a standard relay did not meet the required safety performance level of Type IIIC in EN 574:1996 as referenced in BS EN 1010-1:2004+A1:2010. EN 574:1996 is now replaced by BS EN ISO 13851:2019 and BS EN 1010-1:2004+A1:2010 replaced by BS EN ISO 12643-1:2023.
The product does not meet the requirements of the Supply of Machinery (Safety) Regulations 2008.
Action taken
Making the marketing of the product subject to prior conditions.
Advice to consumers
The original supplier of CCM Premier 92 machines (TCS Finishing Solutions Ltd) is no longer trading. Users with these machines should seek advice from a local machinery guarding provider to bring them into compliance. Risks should be assessed using ‘The Guide To Safe Use Of Power-Operated Paper-Cutting Guillotines’ at https://www.hse.gov.uk/pubns/books/power-guillotines.htm . Users should also refer to the current applicable standards BS EN ISO 12643-1:2023 and BS EN ISO 1264-3:2023.
Additional information
PSD notification number: 2608-0035
Notified by: Health and Safety Executive
Product description
Hydraulic-driven high speed paper cutting guillotine. Please see Annex A in the linked PDF for a picture of the machine nameplate.
Open the OPSS notice
Questions
Why has CCM Premier 92 HPM Premier 92 M10 Paper Guillotine been reported?
CCM Premier 92 HPM Premier 92 M10 Paper Guillotine has been reported because it could hurt the person using it. Products that break, pinch, cut or fail suddenly can cause injuries ranging from cuts to fractures.
How do I know if my product is affected?
Compare the sold between on your product with the details listed under “Check your product” on this page. Only items that match are covered by the notice.
What should I do now?
Stop using it. Read the corrective action below: some notices offer a fix rather than a return.
Can I get a refund or a repair?
Sellers on online marketplaces do not always run recalls themselves, so you may need to ask for your money back. The platform’s help pages explain its buyer protection scheme. Citizens Advice (0808 223 1133), Advice Direct Scotland (0808 164 6000) and Consumerline (0300 123 6262) give free advice if you get stuck.